McKernan - located south of University Avenue NW and east of 114 Street NW
Charter Bylaw 19630 (April 7, 2021)
To allow for the development of a transit-oriented, mid-rise apartment building with street oriented residential uses and a pedestrian scale fronting onto University Avenue NW.
The provision shall apply to Lots 22 - 26, Block 6, Plan 2064S, located south of University Avenue NW and east of 114 Street NW, as shown on Schedule “A” of the Charter Bylaw adopting this Provision, McKernan.
1. | Multi-unit Housing |
2. | Live Work Unit |
3. | Lodging Houses |
4. | Major Home Based Business |
5. | Minor Home Based Business |
6. | Residential Sales Centre |
7. | Supportive Housing |
8. | Fascia On-premises Signs |
9. | Projecting On-premises Signs |
10. | Temporary On-premises Signs |
1. | All Signs shall comply with the General Provisions of Section 59 of the Zoning Bylaw and the regulations found in Schedule 59B of the Zoning Bylaw and the following: | ||||
|
1. | The development shall be in general conformance with the attached appendices. | ||||||||||||
2. | The maximum Floor Area Ratio (FAR) shall be 3.4. | ||||||||||||
3. | The maximum number of Dwellings shall be 132. | ||||||||||||
4. | The maximum Height shall be 23.0 m. | ||||||||||||
5. | The minimum building Setbacks from the Lot lines shall be as follows: | ||||||||||||
|
|||||||||||||
6. | The portions of the Underground Parkade below ground level shall not be subject to required Setbacks and can extend to all Lot lines provided: | ||||||||||||
|
|||||||||||||
7. | Notwithstanding Section 4.5 of this Provision, the portions of the Parking Garage above ground level may project into the required Setbacks on the north, east, and west, provided: | ||||||||||||
|
|||||||||||||
8. | Platform Structures in the form of balconies may project a maximum of 1.5 m into Setbacks. | ||||||||||||
9. | Patios for Dwellings on the first storey shall not extend further into Setbacks than the portions of the Parking Garage above ground level. |
1. | The development shall incorporate design elements to reduce the perceived mass and add architectural interest, including articulation of Façades, using a defined pattern of projections and/or recessions and a variety of exterior building cladding materials and colours. | ||||||||
2. | The Building shall be designed and oriented to face University Avenue NW with entrances that are prominent, clearly visible and distinct. | ||||||||
3. | Dwellings located on the ground floor facing University Avenue NW shall: | ||||||||
|
|||||||||
4. | All building Facades shall have consistent and harmonious finishing materials. | ||||||||
5. | Exterior finishing materials shall be durable, high-quality and appropriate for the development such as, but not limited to: painted Façade, masonry, stone, brick, concrete, cement board, metal cladding/panelling/screening, wood, stucco, and/or glazing. | ||||||||
6. | Decorative and security lighting shall be designed and finished in a manner consistent with the design and finishing of the development and shall be provided to ensure a well-lit environment for pedestrians and to highlight the architectural and landscape features at night. | ||||||||
7. | Night-time light pollution shall be reduced by avoiding over-illumination of the development with the use of low cut-off exterior lighting fixtures. | ||||||||
8. | All mechanical equipment, including roof mechanical units, surface level venting systems and transformers, shall be concealed by screening in a manner compatible with the architectural character of the building or concealed by incorporating it within the building. Ground level vents shall be oriented away from adjacent Sites or on-Site amenities or pedestrian circulation areas. | ||||||||
9. | A minimum 1.83 m high wood screen fence shall be provided for the full length of the east Lot line except within the Setback from University Avenue NW and within 3.0 m of the rear Lane. |
1. | Vehicular access and egress to an Underground Parkade may only be provided: | ||||||||
|
|||||||||
2. | A minimum of one parking space shall be provided for a car-sharing program. | ||||||||
3. | Loading, storage, and waste collection shall be located within the building and screened from view of the adjacent Lane and shall be designed to the satisfaction of the Development Officer in consultation with Subdivision and Development Coordination (Transportation) and City Operations (Waste Management). | ||||||||
4. | Bicycle Parking spaces shall be provided in accordance with the Zoning Bylaw, and the following: | ||||||||
|
1. | Notwithstanding Landscaping Regulations of the Zoning Bylaw, Landscaping shall be in general conformance with the following: | ||||||||||
|
|||||||||||
2. | The required Landscape Plan submitted with a Development Permit application for new building construction shall be prepared by a Landscape Architect registered with the Alberta Association of Landscape Architects (AALA). | ||||||||||
3. | Landscaping shall use plant materials that provide colour throughout the year to enhance the appearance of the development during cold weather months. | ||||||||||
4. | An arborist report and tree preservation plan, to the satisfaction of the Development Officer in consultation with Urban Forestry, shall be submitted with the Development Permit application to determine the impact of the proposed development, including excavation and construction, on the existing boulevard trees along University Avenue NW. If required by the Development Officer, an air spading tool shall be used to determine the amount and size of roots that may need to be cut for the parkade/foundation wall. If: | ||||||||||
|
|||||||||||
5. | A minimum total Amenity Area of 7.5 m2 per Dwelling shall be provided through a combination of the following: | ||||||||||
|
1. | Prior to the issuance of the Development Permit for construction of the principal building, a Wind Impact Study shall be submitted for review. The development shall incorporate design features to minimize adverse microclimatic effects such as wind tunneling, snow drifting, rain sheeting both on and off Site, consistent with the recommendations of the Wind Impact Study. | ||||
2. | Site and building layouts shall include design elements that take the principles of Crime Prevention Through Environmental Design (CPTED) into consideration. These elements may include, but are not limited to, elements that allow for natural surveillance, increase sightlines and use; and high quality interior and exterior lighting. The physical layout and landscaping shall reduce the vulnerability of pedestrians by avoiding areas of concealment or entrapment such as: long public corridor spaces, stairwells, or other movement predictors; avoiding landscaping hazards such as: unpruned trees, rocks that can be thrown, or blind corners; and by locating parking areas close to building access points and using wayfinding mechanisms. The Development Officer may require a Crime Prevention Through Environmental Design assessment prepared by a qualified security consultant, and may apply conditions to the approval of the Development Permit based on the recommendations of the CPTED assessment to promote a safe physical environment. | ||||
3. | Prior to the issuance of a Development Permit, except for Development Permits for demolition, excavation, shoring or signage, the applicant shall submit documentation that demonstrates, to the satisfaction of the Development Officer in consultation with Fire Rescue Services and EPCOR Water Services, that the fire flows and water servicing to the Site will be adequate for the proposed building and construction type, and be in accordance with the City of Edmonton Design and Construction Standards. The Development Officer shall verify that any infrastructure upgrades or systems required to ensure these standards are met shall be implemented in the design of the building and/or through off-site improvements. | ||||
4. | Notwithstanding the other Development Regulations of this Provision, the Appendices of this Provision and Section 720.3(2) of the Zoning Bylaw, in the event that the owner/developer does not obtain a Building Permit and commence construction of the principal building under a valid Development Permit within 7 years of the passage of the Bylaw adopting this Provision, development of the Site shall be in accordance with this Provision, except that: | ||||
|
1. | As a condition of a Development Permit for construction of a principal building, the owner shall enter into an agreement with the City of Edmonton for off-Site improvements necessary to serve the development, such improvements to be constructed at the owner’s cost, and be to the satisfaction of the Development Officer in consultation with Subdivision and Development Coordination (Transportation). The agreement process includes an engineering drawing review and approval process. Improvements to address in the agreement include, but are not limited to: | ||||||
|
|||||||
2. | Prior to the issuance of a development permit for: | ||||||
|
|||||||
3. | The drainage systems required to service the development, including off-site improvements and on-site stormwater management, shall be in general conformance with the Drainage Servicing Report or alternatives to the satisfaction of the Development Officer in consultation with Development Services (Drainage). Such improvements are to be constructed at the owner's cost. |