To allow for ground level retail commercial, offices, and services suitable for the Downtown’s Main Street, Jasper Avenue, and to ensure that infill developments and the retrofitting and preservation of historical and older buildings incorporate human scale design characteristics to enhance a revitalized, dynamic Main Street atmosphere.
Residential Uses |
||||||
2.1. | Home Based Business # | |||||
2.2. | Residential, limited to: | |||||
|
||||||
Commercial Uses # |
||||||
2.3. | Bar | |||||
2.4. | Body Rub Centre | |||||
2.5. | Cannabis Retail Store | |||||
2.6. | Centre City Temporary Parking | a | ||||
2.7. | Cultural Exhibit | |||||
2.8. | Food and Drink Services | |||||
2.9. | Health Service | |||||
2.10. | Hotel | |||||
2.11. | Indoor Sales and Service | |||||
2.12. | Liquor Store | |||||
2.13. | Minor Indoor Entertainment | |||||
2.14. | Office | |||||
2.15. | Residential Sales Centre | |||||
2.16. | Spectator Entertainment Establishment | |||||
Community Uses |
||||||
2.17. | Child Care Service | |||||
2.18. | Community Service | |||||
2.19. | School | |||||
2.20. | Library | |||||
2.21. | Special Event | |||||
Sign Uses |
||||||
2.22. | Fascia Sign, limited to On-premises Advertising | |||||
2.23. | Projecting Sign, not including in the form of a Roof Sign, limited to On-premises Advertising |
Residential Uses |
|||
3.1. | Residential, limited to: | ||
|
|||
Commercial Uses # |
|||
3.2. | Custom Manufacturing | ||
3.3. | Nightclub | ||
Basic Service Uses |
|||
3.4. | Minor Utility | ||
3.5. | Transit Facility | ||
3.6. | Emergency Service | ||
Agricultural Uses |
|||
3.7. | Urban Agriculture | ||
Sign Uses |
|||
3.8. | Fascia Sign, limited to Off-premises Advertising | ||
3.9. | Freestanding Sign, limited to On-premises Advertising | ||
3.10. | Major Digital Sign | ||
3.11. | Minor Digital Sign | ||
3.12. | Projecting Sign, not including in the form of a Roof Sign, limited to Off-premises Advertising |
Residential Uses |
||||||||
4.1. | Home Based Businesses must comply with Section 6.60. | |||||||
4.2. | Residential Uses are not permitted at ground level fronting Jasper Avenue. | |||||||
Commercial Uses |
||||||||
4.3. | Bars | |||||||
|
||||||||
4.4. | Liquor Stores must comply with Section 6.70. | |||||||
4.5. | Body Rub Centres must comply with Section 6.20. | |||||||
4.6. | Cannabis Retail Stores must comply with Section 6.30. | |||||||
4.7. | Centre City Temporary Parking must comply with Section 6.120. | a | ||||||
4.8. | Uses with Drive-through Services must comply with Section 6.110. | |||||||
4.9. | Buildings fronting onto a Street must provide a minimum of 80% Ground Floor Street Frontage for Commercial Uses. | |||||||
Community Uses |
||||||||
4.10. | Child Care Services must comply with Section 6.40. | |||||||
4.11. | Special Events must comply with Section 6.100. | |||||||
Agricultural Uses |
||||||||
4.12. | Urban Agriculture | |||||||
|
||||||||
Sign Uses |
||||||||
4.13. | Signs must comply with the regulations found in Subsections 3 and 6 of Section 6.90. | |||||||
Public Space and Capacity Exceptions |
||||||||
4.14. | The Development Planner may consider a variance to the maximum Public Space or capacity of a Use if adequate mitigation measures are used to reduce negative impacts to on-Site or Abutting Uses, including: | |||||||
|
5.1. | Development must comply with Table 5.1: |
Table 5.1. Floor Area Ratio | ||
---|---|---|
Subsection | Regulation | Value |
5.1.1. | Maximum Floor Area Ratio | 7.0 |
5.2. | Despite Subsection 6 of Section 7.100, a Development Planner may grant a variance to the Maximum Floor Area Ratio, up to an additional 3.0, where the development is compatible with the urban context of the area and adverse environmental impacts, such as sun shadow and wind, are minimized. |
5.3. | Development must comply with Table 5.3: |
Table 5.3. Height Regulations | ||
---|---|---|
Subsection | Regulation | Value |
Height | ||
5.3.1. | Maximum Height | 70.0 m |
Street Wall Height | ||
5.3.2. | Minimum Street Wall Height | 9.0 m |
5.3.3. | Maximum Street Wall Height | 26.0 m |
5.4. | Despite Subsection 6 of Section 7.100, a Development Planner may grant a variance to the Maximum Height, up to an additional 15.0 m, where development is compatible with the urban context of the area and adverse environmental impacts, such as sun shadow and wind, are minimized. | ||||||
5.5. | Despite Subsections 5.3.2 and 5.3.3: | ||||||
|
|||||||
5.6. | Development must comply with Table 5.6: |
Table 5.6. Setbacks | ||
---|---|---|
Subsection | Regulation | Value |
Setbacks Abutting Streets | ||
5.6.1. | Minimum Setback | 0 m |
5.6.2. | Maximum Setback | 2.5 m |
Unless the following applies: | ||
5.6.3. | Minimum Setback Abutting 109 Street NW | 1.5 m |
5.6.4. | Maximum Setback Abutting 109 Street NW | 4.0 m |
5.6.5. | Minimum Setback Abutting 108 Street NW | 3.0 m |
5.6.6. | Maximum Setback Abutting 108 Street NW | 4.5 m |
Setbacks from Abutting Sites | ||
5.6.7. | Required Setback | 0 m |
5.7. | Despite Subsection 5.6, the Development Planner may consider a variance to the Setback regulations in consideration of the existing block face Setback and the Urban Design Framework for Downtown Streets within the Capital City Downtown Plan. |
Street Interface Regulations |
|||||||
6.1. | Developments in this Zone must reflect the requirements outlined in the Urban Design Framework for Downtown Streets within the Capital City Downtown Plan, emphasizing specific boulevard treatments to enhance the pedestrian oriented character of Jasper Avenue. | ||||||
6.2. | Developments must provide multiple points of interaction to facilitate pedestrian interaction, in the form of: | ||||||
|
|||||||
6.3. | The minimum Ground Floor Height is 3.5 m. | ||||||
6.4. | Smaller scale retail spaces must be provided to maintain a rhythm of fine-grained retail at ground level for developments over 1,860 m2. | ||||||
6.5. | All street level Commercial Uses that Abut a Street must provide a primary direct access to the Street. | ||||||
6.6. | Continuous ground level retail and Commercial activities must be provided, with a perceived pattern of small shop Frontages less than or equal to 32.0 m in width at street level. | ||||||
6.7. | The Ground Floor elevation must be within 0.3 m of ground level. Yards adjacent to a public sidewalk must continue the paving materials, finish, and pattern of the public sidewalk. | ||||||
6.8. | The architectural treatment of the building up to the first 26.0 m of Height must adhere to the general alignment of the horizontal and vertical elements of the Abutting and adjacent buildings along the same block face. | ||||||
Entrance Regulations |
|||||||
6.9. | Ground level Commercial Uses must open to the Street rather than an internal atrium. | ||||||
6.10. | Buildings at corners must provide courtyards, major entry ways, or distinctive architectural features consistent with the style of the building or influences on the other corners of the intersection to enhance pedestrian circulation and, where applicable, enhance axial views. | ||||||
6.11. | Buildings must be designed and oriented to face all Streets. | ||||||
6.12. | Entrances for Multi-unit Housing must have: | ||||||
|
Tower Regulations |
|
6.13. | Buildings greater than 26.0 m in Height must have a Tower and Podium configuration that ensures compatibility with the Facades of adjacent, older institutional, or historic buildings. |
6.14. | Development must comply with Table 6.14: |
Table 6.14. Tower Regulations | ||
---|---|---|
Subsection | Regulation | Value |
6.14.1. | Maximum Tower Floor Plate for any portion above a Podium | 900 m2 or 85% of the Podium Floor Plate, whichever is lesser |
6.14.2. | Minimum Tower Stepback at the mid-level of Towers | 4.5 m |
6.14.3. | Minimum separation between Towers on the same Site and Abutting Sites | 25.0 m |
6.15. | Despite Subsection 6.14.1, Developments less than 26 m in Height are not required to provide a Floor Plate reduction. | ||||||||
6.16. | The Development Planner may consider a variance to Subsection 6.14.3, taking into consideration factors such as: | ||||||||
|
|||||||||
6.17. | The top Storeys of a Tower must contribute to the ’signature’ of the building and the city’s skyline through sculpting of the upper Storeys and roofs. | ||||||||
6.18. | Rooftops of Towers must be designed with penthouses to accommodate mechanical penthouses, reduce the heat island effect, facilitate energy efficiency and contribute to a distinctive and unique downtown skyline. The design of the roof may include a combination of: | ||||||||
|
|||||||||
6.19. | Despite Subsection 6.14.1, a minimum 10% reduction in Floor Plate area for the top 4 Storeys of any Tower is required. | ||||||||
6.20. | Wherever Podium roofs are visible from adjacent developments, the development must provide enhancements to improve rooftop aesthetics. Enhancements may include: | ||||||||
|
|||||||||
Facade Regulations |
|||||||||
6.21. | Building Facades must incorporate architectural design details or features that reflect the predominant urban character of Jasper Avenue, as identified in the Urban Design Framework for Downtown Streets within the Capital City Downtown Plan. | ||||||||
6.22. | Building Facades must be strongly articulated at regular increments to add variety, rhythm, and a human scaled dimension along the block face. | ||||||||
6.23. | Buildings must provide articulation such as awnings, canopies, window openings, reveals, offsets, multiple entrances, arcades, columns, quality materials, fenestrations, double Height entrances, parks, plazas, appropriate landscaping, colour, or other architectural features. | ||||||||
6.24. | All exposed building Facades must have consistent and harmonious exterior finishing materials. | ||||||||
6.25. | Exterior finishing materials must be durable, sustainable, high quality, and appropriate within the context of the block face. | ||||||||
6.26. | Infill developments must be sensitive to the design character, scale, Facade, and materials of adjacent buildings within the block face. | ||||||||
Rooftop Regulations |
|||||||||
6.27. | All minor mechanical equipment on a roof of any building must be concealed by screening in a manner compatible with the architectural character of the building, or concealed by incorporating it within the building. |
Amenity Areas |
|||||||
7.1. | Despite Section 5.20 Amenity Areas must be provided in compliance with the following: | ||||||
|
|||||||
7.2. | Developments with Frontage greater than 90.0 m must provide 5% of total Floor Area as open space in the form of plazas, atriums, and publicly accessible open spaces. | ||||||
Landscaping |
|||||||
7.3. | Despite Section 5.60, only deciduous species are allowed in any Setback area Abutting a Street. |