1. |
Where this Section is referenced in a Zone, development must achieve the minimum requirements for inclusive design for: |
|
|
|
|
Minimum Criteria for Shared Areas of a Building
|
|
2. |
The main entrance to a building in which the Dwelling or Sleeping Unit is located must: |
|
|
2.1. |
be Barrier-free; and |
2.2. |
provide a minimum unobstructed doorway width of 0.9 m. |
|
|
3. |
If there is no direct exterior access at ground level to the Dwelling or Sleeping Unit, an internal Barrier-free path of travel with a minimum width of 1.8 m must be provided from the main entrance of the building to the Dwelling or Sleeping Unit. |
|
4. |
If the entrance to the Dwelling or Sleeping Unit is not on the Ground Floor, that Dwelling or Sleeping Unit must be accessible by an elevator. |
|
5. |
Indoor Common Amenity Areas and other shared facilities must be accessible from the Dwelling or Sleeping Unit by a Barrier-free path of travel with a minimum width of 1.8 m. |
|
6. |
The impact of a long Barrier-free path of travel must be minimized by including areas for seating at regular intervals, which must not obstruct the Barrier-free path of travel. |
|
7. |
All doorways along a Barrier-free path of travel must provide a minimum unobstructed width of 0.9 m. |
|
8. |
A minimum 1.8 m unobstructed turning diameter must be provided along all areas of a Barrier-free path of travel. |
|
Minimum Criteria for Dwellings
|
|
9. |
All entrances to the Dwelling must: |
|
|
9.1. |
be Barrier-free; and |
9.2. |
provide a minimum unobstructed doorway width of 0.9 m. |
|
|
10. |
All areas within the Dwelling must provide a Barrier-free path of travel with a minimum width of 1.2 m. |
|
11. |
A minimum 1.5 m unobstructed turning diameter must be provided in all areas of the Dwelling, including but not limited to: |
|
|
11.1. |
entrance areas; |
11.2. |
kitchens; |
11.3. |
stair landings; |
11.4. |
bedrooms; |
11.5. |
along Barrier-free paths; and |
11.6. |
bathrooms. |
|
|
12. |
Despite Subsection 11, where provided, balconies and patios must provide a minimum 1.8 m unobstructed turning diameter and Barrier-free access. |
|
13. |
All doorways within the Dwelling must have a minimum unobstructed width of 0.9 m. |
|
14. |
The following must be included on the same floor as the Barrier-free entrance to the Dwelling: |
|
|
14.1. |
at least 1 bathroom that includes: |
|
14.1.1. |
a Barrier-free tub or shower; and |
14.1.2. |
grab bars installed at the toilet, and at the tub or shower; |
|
14.2. |
a kitchen; |
14.3. |
laundry facilities, if provided within the Dwelling; and |
14.4. |
a minimum of 1 bedroom, unless the Dwelling is designed as a studio. |
|
|
15. |
Despite Subsection 14, a bathroom, kitchen, laundry facility, and bedroom are not required to be on the same floor as a Barrier-free entrance to the Dwelling where a stair lift or elevator provides Barrier-free access to these facilities. |
a |
16. |
If the Dwelling contains more than 1 Storey, and an elevator or stair lift is not provided at the time of construction, the Dwelling must be designed to accommodate the installation of a stair lift or elevator. |
a |
|
16.1. |
To accommodate a stair lift, stairways must: |
|
16.1.1. |
provide access between all floors; |
16.1.2. |
have a minimum width of 1.0 m; and |
16.1.3. |
have a minimum clearance depth of 3.0 m from the stairway at all landings. |
|
16.2. |
To accommodate an elevator, at least 1 closet on each floor must: |
|
16.2.1. |
have a minimum dimension of 2.0 m x 2.0 m; |
16.2.2. |
be vertically aligned with all closets of the same minimum dimensions on each floor; and |
16.2.3. |
be constructed to be able to function as a residential elevator shaft, with floors that can be easily removed, excluding the lowest floor. |
|
|
|
Minimum Criteria for Sleeping Units
|
|
17. |
At least 1 entrance to the Sleeping Unit must: |
|
|
17.1. |
be Barrier-free; and |
17.2. |
provide a minimum unobstructed doorway width of 0.9 m. |
|
|
18. |
All areas within the Sleeping Unit must provide a Barrier-free path of travel with a minimum width of 1.2 m. |
|
19. |
A minimum 1.5 m unobstructed turning diameter must be provided in all areas of the Sleeping Unit. |
|
20. |
All doorways within the Sleeping Unit must have a minimum unobstructed width of 0.9 m. |
|
21. |
At least 1 bathroom must be included on the same floor as, or within, the Sleeping Unit that includes: |
|
|
21.1.1. |
a Barrier-free tub or shower; and |
21.1.2. |
grab bars installed at the toilet, and at the tub or shower. |
|
|