f. |
All mechanical equipment, including roof mechanical units shall be concealed by screening in a manner compatible with the architectural character of the building or shall be concealed by incorporating it within the building roof. |
g. |
All outdoor and display lighting shall be located and arranged so that no direct rays of light are directed at any adjoining properties, or interfere with the effectiveness of any traffic control devices. |
h. |
No outside acoustical (paging and/or loudspeakers) devices shall be permitted. |
i. |
A comprehensive sign design plan shall be submitted and signs shall be allowed in this Provision as provided for in Section 59F of the Zoning Bylaw. |
j. |
Freestanding on-premises signs shall not exceed 8 m (26 feet) in Height along 100 Avenue and shall be perpendicular to the major roadways. |
k. |
Notwithstanding any other provisions of the Zoning Bylaw, individual business identification signs located on the facades of buildings shall be similar in proportion, construction materials and placement. The Sign shall be designed and located so as to ensure that the signage does not detract from the overall appearance of the development and is not obtrusive, having regard to the scale of the buildings on the Site and to the distance of the building Setback. |
l. |
All on-site services for power, telephone and C.A.T.V. shall be underground. Underground power services shall also be provided for Signs requiring such services. |
m. |
Vehicular entrances and exits, as well as on-site and off-site traffic and pedestrian routes, shall be located and designed in a manner that provides a clearly defined, safe, efficient and convenient circulation pattern for both on-site and off-site vehicular traffic and pedestrian movements, including handicapped movements. Loading bays shall be located in such a manner as not to impede the safe and efficient flow of traffic and pedestrian movement to minimize impacts on adjacent land uses. |
n. |
Conceptual Landscape Plans shall be submitted, with the initial Development Permit Application, for review by the Development Officer. Prior to the issuance of the Development Permit, detailed Landscaping Plans shall be submitted to and approved by the Development Officer. All Landscaping Plans shall ensure a high standard of appearance and a sensitive transition for the surrounding land uses. |
o. |
An application for a new development or for an addition to existing building(s) shall be accompanied by a Site Plan that shows the location of easement area(s) for all existing and proposed servicing infrastructure on the Site. The Development Officer, in consultation with the affected utility departments, shall require that the minimum building Setbacks and the minimum Width of landscaped Yards be adjusted where such adjustments may be necessary to ensure that proposed buildings do not conflict with existing or proposed servicing infrastructure; and that the type, amount and location of Landscaping, including berms, can be provided in a manner that does not conflict with existing or proposed servicing infrastructure. |
p. |
All development on a Site shall be constructed using consistent architectural themes and high quality exterior finish including roof lines and finish materials. |
q. |
A minimum building Setback of 14 m shall be provided adjacent to 100 Avenue. |
r. |
There shall be no chain link fencing or barbed-wire combinations forward or frontward of the mid-point of the principal building located on the Site. Existing fencing around the communication tower will be retained. |
s. |
Landscaped Yards with a minimum Width of 7.5 m shall be provided along the north side of 100 Avenue. |
t. |
Within the Yards specified above, a minimum of five deciduous trees (with a minimum caliper of 6 cm), four coniferous trees (with a minimum Height of 3.0 m), and 25 shrubs shall be required for each 35.0 m of lineal Yard Frontage. A continuous screen, an average of 0.75 m in Height, shall be provided within the required Yard, through a combination of berming and/or shrub planting. |
u. |
Gas Bars, Minor Service Stations, and Rapid Drive-through Vehicle Services shall be developed in accordance with the following additional criteria: |
|
i. |
in addition to the requirements of Section 72 of the Zoning Bylaw, any canopy over a gas pump island shall be no closer that 3.0 m to any boundary of the Site and shall be designed and finished in a manner consistent with the design, finishing and Height of the principal building, such that the canopy is not obtrusive and maintains consistency with the eave line of the principal building; |
ii. |
the canopy area shall not be included in the calculation of the Site Coverage; |
iii. |
all pump islands shall be located at least 6.0 m from any boundary of the Site, parking area on the Site, or laneways intended to control traffic circulation on the Site; and |
iv. |
the design, finishing, lighting and siting of development, including the orientation of gas pump islands and service bays shall achieve a compatible relationship with surrounding development and a high standard of appearance when viewed from adjacent roadways. |
|