Westmount - located south of 102 Avenue NW and west of Clifton Place NW
Charter Bylaw 19857 (September 10, 2021)
To accommodate a high rise residential building that is architecturally unique with high quality design and that provides a pedestrian friendly streetscape.
This Provision shall apply to Lots 2-4, Block B, Plan 2955EO, located south of 102 Avenue NW and west of Clifton Place NW, as shown on Schedule “A” of the Charter Bylaw, adopting this Provision, Westmount.
1. | Live Work Unit |
2. | Lodging Houses |
3. | Minor Home Based Business |
4. | Multi-Unit Housing |
5. | Residential Sales Centre |
6. | Supportive Housing |
7. | Fascia On-premises Signs |
8. | Freestanding On-premises Signs |
9. | Projecting On-premises Signs |
1. | Signs shall comply with the General Provisions of Section 59 of the Zoning Bylaw and the regulations found in Schedule 59B of the Zoning Bylaw. |
2. | Residential Sales Centres shall be limited to the sale or leasing of on-Site condominium or rental Dwellings. |
1. | The development shall be in general conformance with the attached appendices. | ||||||||
2. | Grade shall be taken from the north east corner of the property for the purposes of determining the Height of any structures, except for the Underground Parkade. | ||||||||
3. | Grade shall be taken from the southwest corner of the property for the purposes of determining the Height of the Underground Parkade. | ||||||||
4. | Any portion of an Underground Parkade that is exposed shall be designed and articulated to contribute to the overall urban design aesthetic of Clifton Place. | ||||||||
5. | The maximum Height shall be 55 m. | ||||||||
6. | The maximum pedestal Height shall be 6.0 m. | ||||||||
7. | The maximum Underground Parkade Height shall be 3.0 m. | ||||||||
8. | The maximum Floor Area Ratio shall be 3.0. | ||||||||
9. | The Underground Parkade shall not be included in the calculation of Floor Area Ratio. | ||||||||
10. | The maximum Tower Floor Plate shall be 650 m2. | ||||||||
11. | The maximum number of Dwellings shall be 55. | ||||||||
12. | The minimum building Setbacks shall be: | ||||||||
|
|||||||||
13. | The minimum Tower Setbacks shall be: | ||||||||
|
|||||||||
14. | Architectural features and structures on the pedestal, such as decorative walls or weather protection features including awnings and canopies may project a maximum of 9.5 m into the east and west Setbacks. | ||||||||
15. | The Underground Parkade shall be permitted to extend to the Lot Lines. |
1. | All mechanical equipment, including roof mechanical units and surface level venting systems and transformers, shall be screened in a manner compatible with the architectural character of the building or be concealed by incorporating it within the building. Ground level vents shall be oriented away from adjacent Sites or on-Site amenity or pedestrian circulation areas. |
2. | The Underground Parkade ramp retaining walls that are visible from the street shall be architecturally treated and articulated. |
3. | The building Façades shall incorporate design elements to reduce the perceived mass and add architectural interest, including an articulated tower with two offset vertical volumes. The building shall be finished with high quality materials on all elevations that may include, but are not limited to, stone, brick, wood, concrete, exterior insulation and finishing system panels, and/or glass. The use of vinyl or masonry stucco as a finishing material shall not be permitted. |
1. | Details regarding the location of on-street parallel parking, on-street commercial loading and passenger drop-off zones shall be to the satisfaction of the Development Officer in consultation with Subdivision and Development Coordination (Transportation). |
2. | The waste and recycling storage area shall be located within the building. The outdoor collection area shall be located beside the property line abutting Clifton Place and designed to the satisfaction of the Development Officer in consultation with Waste Management Services and Subdivision and Development Coordination (Transportation). |
1. | The required Landscape Plan submitted with a Development Permit application for new building construction shall be prepared by a Landscape Architect registered with the Alberta Association of Landscape Architects (AALA). | ||||||
2. | In addition to meeting the requirements of the Zoning Bylaw, the Landscape Plan shall: | ||||||
|
|||||||
3. | Decorative and security lighting shall be designed and finished in a manner consistent with the design and finishing of the development and shall be provided to ensure a well-lit environment for pedestrians, to accentuate building elements, and highlight the development in winter months. Exterior lighting associated with the development shall be designed to minimize impact on an adjacent property. Exterior lighting above the third storey of the building shall be directed downwards. A detailed exterior lighting plan shall be provided to the satisfaction of the Development Officer. | ||||||
4. | Streetscaping shall be enhanced from the typical landscaping to include concrete sidewalks, shrubs, perennial, trees, benches, and lighting incorporated in clusters that are integrated with the overall site planning and building architecture, to the satisfaction of the Development Officer in consultation with Subdivision and Development Coordination (Transportation). |
1. | Site and building layouts shall include design elements that take the principles of Crime Prevention Through Environmental Design (CPTED) into consideration. These elements may include, but are not limited to, elements that allow for natural surveillance, increased sightlines and use; and high quality interior and exterior lighting. The physical layout and landscaping shall reduce the vulnerability of pedestrians by avoiding areas of concealment or entrapment such as: long public corridor spaces, stairwells, or other movement predictors; avoiding landscaping hazards such as: unpruned trees, rocks that can be thrown, or blind corners; and by locating parking areas close to building access points and using wayfinding mechanisms. The Development Officer may require a Crime Prevention Through Environmental Design assessment prepared by a qualified security consultant, and may apply conditions to the approval of the Development Permit based on the recommendations of the CPTED assessment to promote a safe physical environment. |
2. | Where appropriate, pedestrian wayfinding signage shall be provided to the satisfaction of the Development Officer and Transportation Services. |
3. | Prior to the issuance of a Development Permit, a Wind Impact Study shall be submitted for review. The development shall incorporate design features to minimize adverse microclimatic effects such as wind tunneling, snow drifting, rain sheeting both on and off Site, consistent with the recommendations of the Wind Impact Study. |
1. | As a condition of the Development Permit for the new building the owner shall provide a total contribution of $216,000 towards the following: | ||||||||||||||||||||||
|
|||||||||||||||||||||||
2. | The owner shall register a 3.0 m wide public access easement along the south Lot line to provide space for a trail connection to Clifton Place, in general accordance with Appendix III. The owner shall not be responsible for developing the trail connection. | ||||||||||||||||||||||
3. | The owner(s) shall enter into a Sidewalk Utility Right-Of-Way Agreement for those portions of Clifton Place sidewalk that are located within private property abutting the Site. | ||||||||||||||||||||||
4. | The owner(s) must enter into an agreement with the City of Edmonton for off-site improvements necessary to serve the development. The agreement process includes an engineering drawing review and approval process. Improvements to be addressed in the Agreement include, but are not limited to the following: | ||||||||||||||||||||||
|